IQ modulation in practice: carrier leakage and the image
A visual tour of IQ modulator impairments (offset, gains, quadrature, cross-coupling and delay) and of the single model that lets you compensate them.
On this page
- A real signal, two numbers per instant
- The real chain
- Five impairments, two symptoms
- DC offset: the circle shifts
- Gain imbalance: the ellipse is two circles
- Quadrature error: axes that are not perpendicular
- Cross-coupling between branches: it depends on the circuit
- Differential delay: the “bat wings”
- One model for everything
- Calibrating without fooling yourself
- In summary
- The full report
- References
You generate a clean baseband tone, convert it with two DACs, run it through an IQ modulator and look at the spectrum analyzer. You expected one line at , and three show up: yours, another one right at the local oscillator frequency , and a third, smaller one mirrored at . The middle one is carrier leakage; the mirrored one is the image.
Neither is mysterious. Both can be read from a single picture: the complex-envelope vector seen from a frame that rotates with the local oscillator. In this article I go through that picture and what each hardware impairment does to it: DC offset, gain imbalance, quadrature error, cross-coupling between branches and differential delay. In the end, all of them fit into one model that can be inverted to predistort the signal.
The complete derivations, circuits and validity conditions are in the full report, which you can download at the end.
A real signal, two numbers per instant
An IQ modulator takes two real signals, and , and produces1
is the complex envelope: a vector in the plane whose coordinates are and . It is worth not confusing the orthogonality of the axes with a time relationship between the signals: and can be any two real functions. Sine and cosine only appear in a particular case, a tone [1].
That case is precisely the most instructive one. With , the vector traces a circle of radius rotating at , and the output is a single tone at . With a negative , the vector rotates the other way and the tone falls below the LO.

That rotating frame is the key to reading everything that follows. If we “ride” on the local oscillator, every spectral line around becomes a vector:
- a static vector is energy exactly at (carrier leakage);
- a vector rotating counterclockwise at is a line at ;
- a vector rotating clockwise at is a line at (the image of our tone).
Ideal tone: a single rotating vector tracing a perfect circle. On the right, both coordinates over time.
In the figures, blue is the desired signal, red the image and gray the offset; the vectors are chained, so their sum traces the envelope trajectory, and the dashed circle is the ideal trajectory. In the animations, the middle inset magnifies the small vector, which is barely visible at scale, and the right panel shows (blue) and (red) over time.
The real chain
In practice, and come from memory or from a digital generator, go through two DACs with a common clock, are amplified and filtered, and reach two mixers fed by the LO through a 0°/90° splitter. The two branches are summed, and the RF is amplified and filtered again.
Before reaching the mixer, the DAC itself already distorts the signal. The zero-order hold has a response: it drops dB at and leaves sampling images around every multiple of . With MHz and a MHz band of interest, the band edge sits at dB. You can pre-compensate within the band [2], but that gain eats headroom: to avoid saturation, the table must be normalized to the band-edge level. And pre-compensation does not remove the images; that is the job of the reconstruction filter, which in this example must transition between 25 and 35 MHz.

A correction common to I and Q compensates a common response. What is interesting, and what produces leakage and image, are the differences between branches.
Five impairments, two symptoms
All the impairments below produce one of two symptoms: a static vector appears (LO leakage) or a vector rotating the other way appears (image) [3]. To quantify the image I always use the same convention:
where and are the complex amplitudes of the desired component and of the image. An image level of dBc is an image rejection of 40 dB.
DC offset: the circle shifts
An offset in each branch adds a constant to the envelope: . In the LO frame it is a fixed vector, so the circle shifts and a line appears in the RF exactly at :
An offset of 5 % of the desired amplitude leaves the leakage at dBc.
Offset of and (5 % of the amplitude): the gray vector is static and shifts the center of the trajectory. The inset magnifies the offset, which is barely visible on the main scale.
The correction is to subtract the offset, either digitally before the DACs (which costs range) or with auxiliary DACs afterwards (which preserves the range of the signal DACs). In practice a single pass is not enough: the real leakage is the vector sum of the converted offset and the direct LO feedthrough to the output, and the two adjustment directions are usually not orthogonal. You have to alternate I and Q adjustments until the minimum stops improving.
Gain imbalance: the ellipse is two circles
If the branches have different gains and , the circle becomes an ellipse. The revealing step is to rewrite it as:
The term is the image: for a tone it rotates the other way. The ellipse is nothing but the sum of two vectors rotating in opposite directions.

The image level is . A ±5 % imbalance (, ) leaves the image at dBc; reaching 40 dB of rejection requires an imbalance of ±1 % or less, and that is with no other error present. Note that these are two different metrics: equalizing the gains cancels the image, but the desired amplitude also depends on their average.
A ±5 % imbalance: the red vector, chained to the blue one, rotates backwards. It is little more than a correction to the trajectory, yet it already leaves the image at dBc.
Quadrature error: axes that are not perpendicular
If the two carriers are not exactly 90° apart, with phase errors and , the effective axes of the plane are no longer orthogonal. With and , the model takes the same form again:
The common phase only rotates everything; the difference is what creates the image and tilts the ellipse. A quadrature error of 1° leaves the image at dBc.
Phase errors of 27° and 9° (exaggerated so they show): the ellipse is tilted and the image, in the inset, rotates opposite to the desired signal.
Gain and phase combine coherently:
You cannot add the dB levels of each error as if they were independent powers. Improving the phase may go unnoticed if the gain dominates, and vice versa.
Cross-coupling between branches: it depends on the circuit
Both branches live on the same board: parasitic capacitances, shared supplies, return paths. In general, the output is a transfer matrix that mixes and , and its frequency dependence cannot be inferred by naming the mechanism (“it’s capacitive”, “it’s inductive”): it is set by the source and load impedances.
A concrete example: two sources with series resistance , loads and a capacitance between branches.
Solving the circuit, with and , the image-to-desired ratio is : dBc for , dBc for , and 0 dBc when the coupling is very strong. In that limit the trajectory collapses into a line at 45°: desired component and image have the same magnitude, and no finite predistortion can recover the signal, because two degrees of freedom go through a single direction.
Capacitive coupling with and nF for a 125 kHz tone (): image at dBc.

Moreover, unlike quadrature error, the image grows with the tone frequency: two tones of equal amplitude have different images.
Differential delay: the “bat wings”
If one branch arrives earlier than the other, because of traces of different length or different filters, each tone sees a phase shift that grows with its frequency. For a differential delay :
A 0.5 µs differential delay with a 125 kHz tone: for a single tone it looks like a quadrature error, and the image sits at dBc.
For a single tone, a delay cannot be told apart from a phase error. The difference shows up when the tone changes: the image is zero at and grows at 20 dB per decade; plotted in dB around zero, it looks like a pair of bat wings. The number worth remembering: for 40 dB of rejection up to 25 MHz, the differential delay must be below about 127 ps, and that is with no other errors.

The most useful diagnostic appears when delay and quadrature error combine: the image null is no longer at and moves to
If, when sweeping tones, the image minimum is not at the center, you have both at the same time. Correcting the LO phase brings the minimum back to , but the delay is still there.

One model for everything
Offset, gain, phase, symmetric coupling and delay (at a given frequency) all end up in the same form:
is the gain and phase of the desired signal, produces the image and is the leakage referred to the LO frame.2
Two practical consequences:
- Errors do not add up. When two blocks are chained, and . The order matters, and so does the physical point where each correction is injected.
- The model can be inverted. To obtain the desired envelope at the output, you generate
That formula corrects gain, phase, cross-mixing and offset at once [4]. Near the denominator vanishes: that is the strong-coupling case, where the inverse amplifies noise and estimation errors.
When the errors depend on frequency, the coefficients become responses: . That couples each frequency with its mirror, and the correction becomes a matrix of filters. A scalar correction tuned with a single tone does not prove that the whole band is compensated: a delay, for example, needs a phase proportional to frequency (a fractional-delay filter).
Calibrating without fooling yourself
A reasonable sequence, with a test tone that separates the signal, the LO and the image in the spectrum [5, 3]:
- Check that nothing saturates and measure the uncorrected state.
- Minimize LO leakage by alternating the I and Q DC adjustments.
- With a tone, adjust differential gain and quadrature, alternating, and keep an eye on the desired amplitude.
- Repeat with tones spread across the band, positive and negative, including some near zero (but not at zero, where signal and image coincide).
- If the image changes systematically with frequency, adjust a differential delay or estimate the full matrix, and check the conditioning.
- Measure everything again with all corrections applied together.
- Validate with a representative signal, such as a chirp or a multitone.
In summary
- In the LO frame, carrier leakage is a still vector and the image is a vector rotating backwards. With that mental picture you can diagnose almost everything.
- Gain, phase, coupling and delay are different paths to the same conjugate term ; what changes is how it depends on frequency, and that dependence is the best clue to which one dominates.
- Minimizing the image is necessary but not sufficient: you also have to preserve the amplitude and phase of the desired signal, and verify across the whole band.
The full report
This article summarizes a longer report that develops everything in detail: the modulation and Fourier conventions, the finite-duration linear chirp, the DAC response, the nodal solution of the coupling circuit, the inversion of the frequency-dependent model and the calibration procedure.
The first version of these notes dates from 2015. This is a rewrite: all figures and animations were computed from the model equations; they are simulations, not measurements of real hardware.
Notes
References
- Lyons, R. (2000). Quadrature Signals: Complex, But Not Complicated. DSP Training. ↩
- Integrated, M. (2012). Equalizing Techniques Flatten DAC Frequency Response. Application note 3853. ↩
- Nash, E. (2009). AN-1039: Correcting Imperfections in IQ Modulators to Improve RF Signal Fidelity. Analog Devices. ↩
- Xu, X., & Wen, K. (2007). Modeling and Compensation of a Non-Ideal I/Q-Modulator. Master's thesis, Chalmers University of Technology (report EX083/2007). ↩
- Hansen, J. (2013). Vector Modulation and Frequency Conversion Fundamentals. Agilent Technologies. ↩
Note